Mostrar el registro sencillo de la publicación
Performance analysis of a VLC system applied to a hospital environment for IoT-based smart patient monitoring
dc.contributor.author | Fernández, Benjamín | |
dc.contributor.author | Palacios Játiva, Pablo | |
dc.contributor.author | Azurdia-Meza, Cesar A. | |
dc.contributor.author | Boettcher, Nicolás | |
dc.contributor.author | Zabala-Blanco, David | |
dc.contributor.author | Gutiérrez Gaitán, Miguel | |
dc.date.accessioned | 2024-10-08T13:49:16Z | |
dc.date.available | 2024-10-08T13:49:16Z | |
dc.date.issued | 2024 | |
dc.identifier.uri | http://repositorio.ucm.cl/handle/ucm/5710 | |
dc.description.abstract | This article investigate the deployment of effective communication networks for smart IoT-based smart patient monitoring in medical facilities, advocating for the adoption of Visible Light Communication (VLC) technology. Initially, the physical scenario is analyzed, taking into account factors such as line-of-sight (LOS) and nonline-of-sight (NLOS) channel components. Furthermore, a transmitter is designed to offer a substitute in the event of potential interruptions due to patient motion or loss of line-of-sight elements. The performance of the proposed system is verified under certain performance metrics, such as the Channel Impulse Response (CIR) and the Cumulative Distribution Function (CDF), with respect to power measurements at different points. The results highlight the effects that NLOS rays have on the received data and the received power. Therefore, this study serves as a step towards the development of more sophisticated systems for patient monitoring using enabling technologies such as VLC. | es_CL |
dc.language.iso | en | es_CL |
dc.rights | Atribución-NoComercial-SinDerivadas 3.0 Chile | * |
dc.rights | Atribución-NoComercial-SinDerivadas 3.0 Chile | * |
dc.rights.uri | http://creativecommons.org/licenses/by-nc-nd/3.0/cl/ | * |
dc.source | International Symposium on Communication Systems, Networks and Digital Signal Processing CSNDSP, 14, 615-620 | es_CL |
dc.subject | E-HEALTH | es_CL |
dc.subject | IoT | es_CL |
dc.subject | Optical channels | es_CL |
dc.subject | Smart patient monitoring | es_CL |
dc.subject | Visible light communication (VLC) | es_CL |
dc.title | Performance analysis of a VLC system applied to a hospital environment for IoT-based smart patient monitoring | es_CL |
dc.type | Article | es_CL |
dc.ucm.indexacion | Scopus | es_CL |
dc.ucm.uri | ieeexplore.ieee.org/document/10636464 | es_CL |
dc.ucm.doi | doi.org/10.1109/CSNDSP60683.2024.10636464 | es_CL |
Ficheros en la publicación
Ficheros | Tamaño | Formato | Ver |
---|---|---|---|
No hay ficheros asociados a esta publicación. |